HU00980 |
SVC, V7000 |
Critical
|
Enhanced recovery procedure for compressed volumes affected by APAR HU00898. For more details refer to this Flash
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems running v7.3 or later that are using compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.13 |
Compression |
HU00891 |
All |
High Importance
|
The extent database defragmentation process can create duplicates whilst copying extent allocations resulting in a node warmstart to recover the database
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems running v7.3 or later using Thin Provisioning |
Trigger |
None |
Workaround |
None |
|
7.3.0.13 |
Thin Provisioning |
HU00936 |
All |
Suggested
|
During the volume repair process the compression engine restores a larger amount of data than required leading to the volume being offline
(show details)
Symptom |
Offline Volumes |
Environment |
Systems running v7.3 or later that are using compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.13 |
Compression |
HU01029 |
SVC |
Suggested
|
Where a boot drive has been replaced with a new unformatted one, on a DH8 node, the node may warmstart when the user logs in as superuser to the CLI via its service IP or they login to the node via the service GUI. Additionally where the node is the config node this may happen when the user logs in as superuser to the cluster via CLI or management GUI
(show details)
Symptom |
Single Node Warmstart |
Environment |
DH8 clusters running v7.3 or later |
Trigger |
Replace boot drive with new, uninitialised drive. Attempt to login to service assistant as "superuser" |
Workaround |
Send necessary service commands to the node from another node in the cluster. Put node into service and resync the drive |
|
7.3.0.13 |
|
HU01043 |
SVC |
Suggested
|
Long pause when upgrading
(show details)
Symptom |
None |
Environment |
DH8 clusters upgrading to v7.5, or later, that are using compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.13 |
Compression, System Update |
HU00898 |
SVC, V7000 |
HIPER
|
Potential data loss scenario when using compressed volumes on SVC and Storwize V7000 running software versions v7.3, v7.4 or v7.5. For more details refer to this Flash
(show details)
Symptom |
None |
Environment |
Systems running v7.3 or later that are using compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.12 |
Compression |
HU00671 |
V7000, V5000, V3700, V3500 |
Critical
|
1691 error on arrays when using multiple FlashCopies of the same source. For more details refer to this Flash
(show details)
Symptom |
None |
Environment |
Systems running v7.3 or later using FlashCopy |
Trigger |
Start and stop of FlashCopy mappings when there are multiple FlashCopies of the same source volume |
Workaround |
None |
|
7.3.0.12 |
Backend Storage, FlashCopy |
HU00901 |
All |
Suggested
|
Incorrect read cache hit percentage values reported in TPC
(show details)
Symptom |
None |
Environment |
Customers using TPC with Systems running v7.3 or later |
Trigger |
None |
Workaround |
None |
|
7.3.0.12 |
System Monitoring |
HU00494 |
All |
High Importance
|
Node warmstart caused by timing window when handling XCOPY commands
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with VMware hosts |
Trigger |
None |
Workaround |
Disable VAAI where possible |
|
7.3.0.11 |
Hosts |
HU00516 |
SVC, V7000 |
High Importance
|
Node warmstart due to software thread deadlock
(show details)
Symptom |
Single Node Warmstart |
Environment |
SVC DH8 or V7000 Generation 2 systems running v7.3 or later with VMware hosts using VAAI CAW feature |
Trigger |
VAAI CAW commands |
Workaround |
None |
|
7.3.0.11 |
Hosts |
HU00666 |
SVC, V7000, V5000, V3700 |
High Importance
|
Upgrade from v7.2.0 stalls due to dependent volumes
(show details)
Symptom |
None |
Environment |
Systems using Global Mirror |
Trigger |
Upgrading from v7.2.0 whilst Global Mirror relationships are active |
Workaround |
Stop Global Mirror relationships or consistency groups before performing upgrade |
|
7.3.0.11 |
Global Mirror |
HU00672 |
SVC, V7000 |
High Importance
|
Node warmstart due to compression stream condition
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.11 |
Compression |
HU00676 |
SVC, V7000 |
High Importance
|
Node warmstart due to compression engine restart
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.11 |
Compression |
HU00752 |
All |
High Importance
|
Email notifications and call home stops working after updating to v7.3.0.10
(show details)
Symptom |
None |
Environment |
All Systems running v7.3.0.10 |
Trigger |
None |
Workaround |
None |
|
7.3.0.11 |
System Monitoring |
HU00761 |
V7000, V5000, V3700, V3500 |
High Importance
|
Array rebuild fails to start after a drive is manually taken offline
(show details)
Symptom |
None |
Environment |
All |
Trigger |
Manually changing drive state to offline |
Workaround |
Use the 'charraymember' cli command to initiate rebuild |
|
7.3.0.11 |
Backend Storage |
HU00711 |
All |
Suggested
|
GUI response slow when filtering a large number of volumes
(show details)
Symptom |
None |
Environment |
All |
Trigger |
None |
Workaround |
Use CLI to list or perform actions on volumes |
|
7.3.0.11 |
Graphical User Interface |
HU00680 |
V7000 |
HIPER
|
Compressed volumes go offline due to false detection event. Applies to V7000 Generation 2 systems only running v7.3.0.9 or v7.4.0.3
(show details)
Symptom |
Offline Volumes |
Environment |
V7000 Gen2 systems with compressed volumes |
Trigger |
Following update to v7.3.0.9 or v7.4.0.3 |
Workaround |
None |
|
7.3.0.10 |
Compression |
HU00654 |
SVC, V7000 |
HIPER
|
Loss of access to data when FlashCopy stuck during a Global Mirror Change Volumes cycle
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems using Global Mirror with Change Volumes |
Trigger |
Start of Global Mirror change volume cycle |
Workaround |
None |
|
7.3.0.9 |
Global Mirror with Change Volumes |
HU00658 |
SVC, V7000, V5000, V3700 |
HIPER
|
Global Mirror source data may be incompletely replicated to target volumes. For more details refer to this Flash
(show details)
Symptom |
Data Integrity Loss |
Environment |
Systems using Global Mirror |
Trigger |
Environments in which the secondary SVC cluster or Storwize system is running or has previously been running a v7.2.0 or v7.3.0 release earlier than v7.2.0.11 or v7.3.0.9 |
Workaround |
None |
|
7.3.0.9 |
Global Mirror |
HU00655 |
V7000, V5000, V3700, V3500 |
Critical
|
Loss of access to data if a PSU in two different enclosures suffers an output failure simultaneously (whilst AC input is good)
(show details)
Symptom |
Loss of Access to Data |
Environment |
Storwize systems |
Trigger |
PSU DC output failure in two separate enclosures simultaneously |
Workaround |
None |
|
7.3.0.9 |
Reliability Availability Serviceability |
HU00528 |
V7000, V5000, V3700, V3500 |
High Importance
|
Single PSU DC output turned off when there is no PSU hardware fault present
(show details)
Symptom |
Loss of Redundancy |
Environment |
Storwize systems |
Trigger |
None |
Workaround |
None |
|
7.3.0.9 |
Reliability Availability Serviceability |
HU00629 |
SVC, V7000 |
High Importance
|
Performance degradation triggered by specific I/O pattern when using compressed volumes due to optimisation issue
(show details)
Symptom |
Performance |
Environment |
Systems with compressed volumes |
Trigger |
Specific I/O pattern when using compressed volumes |
Workaround |
None |
|
7.3.0.9 |
Compression |
HU00636 |
V3700, V3500 |
High Importance
|
Livedump prepare fails on V3500 & V3700 systems with 4GB memory when cache partition fullness is less than 35%
(show details)
Symptom |
None |
Environment |
V3500 & V3700 systems with 4GB memory in each node canister |
Trigger |
When running 'preplivedump' command or collecting Snap option 4 |
Workaround |
None |
|
7.3.0.9 |
Support Data Collection |
HU00637 |
SVC, V7000, V5000 |
High Importance
|
HP MSA P2000 G3 controllers running a firmware version later than TS240P003 may not be recognised by SVC/Storwize
(show details)
Symptom |
Configuration |
Environment |
Systems virtualising HP MSA P2000 G3 controllers |
Trigger |
When initialising MDisks for an HP MSA P2000 G3 controller |
Workaround |
None |
|
7.3.0.9 |
Storage Virtualisation |
HU00646 |
SVC, V7000, V5000, V3700 |
High Importance
|
Easy tier throughput reduced due to Easy tier only moving 6 extents per 5 minutes regardless of extent size
(show details)
Symptom |
Performance |
Environment |
Systems running v7.3 or later with EasyTier enabled |
Trigger |
None |
Workaround |
None |
|
7.3.0.9 |
EasyTier |
HU00648 |
SVC, V7000 |
High Importance
|
Node warmstart due to handling of parallel reads on compressed volumes
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with compressed volumes |
Trigger |
Reads to compressed volume(s) |
Workaround |
None |
|
7.3.0.9 |
Compression |
HU00660 |
SVC, V7000 |
High Importance
|
Reduced performance on compressed volumes when running parallel workloads with large block size
(show details)
Symptom |
Performance |
Environment |
Systems with compressed volumes |
Trigger |
Host workloads with large block size combined with high host queue depth |
Workaround |
Lower maximum host I/O size and queue depth (field cases have shown that setting host MAX XFER SIZE to 128 KB and lowering the queue depth help improve performance) |
|
7.3.0.9 |
Compression |
II14771 |
SVC, V7000 |
High Importance
|
Node warmstart due to compression/index re-writing timing condition
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.9 |
Compression |
IT04911 |
All |
High Importance
|
Node warmstarts due to RAID synchronisation inconsistency
(show details)
Symptom |
Single Node Warmstart |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.9 |
Backend Storage |
IT06407 |
SVC, V7000 |
High Importance
|
Node warmstart due to compressed volume metadata
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with compressed volumes |
Trigger |
Reads/writes to compressed volume(s) |
Workaround |
None |
|
7.3.0.9 |
Compression |
HU00305 |
SVC, V7000, V5000 |
Suggested
|
System unable to detect and use newly added ports on EMC VMAX
(show details)
Symptom |
Performance |
Environment |
Systems virtualising EMC VMAX |
Trigger |
Add new paths from system to EMC VMAX |
Workaround |
None |
|
7.3.0.9 |
Backend Storage |
HU00389 |
SVC, V7000, V5000 |
Suggested
|
When a Storwize system is configured as a backend storage subsystem for an SVC or another Storwize system, the port statistics count the traffic between these two systems as remote cluster traffic instead of host to storage traffic (e.g. in TPC Port to Remote Node Send Data Rate instead of Port to Controller Send Data Rate)
(show details)
Symptom |
None |
Environment |
SVC or Storwize systems with another Storwize system virtualised as a backend controller |
Trigger |
None |
Workaround |
None |
|
7.3.0.9 |
System Monitoring |
HU00653 |
V7000, V5000, V3700, V3500 |
Suggested
|
1691 RAID inconsistencies falsely reported due to RAID incomplete locking issue
(show details)
Symptom |
None |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.9 |
Backend Storage |
HU00656 |
All |
Suggested
|
Increase in reported CPU utilisation following upgrade to v7.2.0 or higher. For more details refer to this Flash
(show details)
Symptom |
None |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.9 |
System Monitoring |
HU00448 |
SVC, V7000 |
Critical
|
Increased latency on SVC and V7000 systems running v7.3 when using compressed volumes due to compression engine memory management
(show details)
Symptom |
Performance |
Environment |
Systems with compressed volumes |
Trigger |
Heavy volumes of reads/writes to compressed volume(s) |
Workaround |
None |
|
7.3.0.8 |
Compression |
HU00526 |
SVC, V7000 |
Critical
|
Node warmstarts caused by very large number of 512 byte write operations to compressed volumes
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems with compressed volumes |
Trigger |
Large number of 512 byte write operations to compressed volumes |
Workaround |
None |
|
7.3.0.8 |
Compression |
HU00539 |
SVC, V7000 |
Critical
|
Node warmstarts after stopping and restarting FlashCopy maps with compressed volumes as target of the map
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems using FlashCopy and compressed volumes |
Trigger |
Stopping and restarting FlashCopy maps with compressed volumes as the target |
Workaround |
None |
|
7.3.0.8 |
FlashCopy, Compression |
IT05219 |
SVC, V7000 |
Critical
|
Compressed volumes offline on systems running v7.3 release due to decompression issue
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems with compressed volumes |
Trigger |
Reads/writes to compressed volume(s) |
Workaround |
None |
|
7.3.0.8 |
Compression |
HU00463 |
SVC, V7000 |
High Importance
|
Increased host I/O response time to compressed volumes on v7.3.0, for specific I/O workloads
(show details)
Symptom |
Performance |
Environment |
Systems with compressed volumes |
Trigger |
Specific I/O workloads to compressed volumes |
Workaround |
None |
|
7.3.0.8 |
Compression |
HU00472 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node restarts leading to offline volumes when using Flashcopy or Remote copy
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems using FlashCopy and/or Global Mirror |
Trigger |
Start and stop of a FlashCopy or Global Mirror map followed by a node reboot |
Workaround |
Any offline volumes can be brought back online by starting or removeing the associated FlashCopy/Remote copy mappings |
|
7.3.0.8 |
FlashCopy, Global Mirror, Global Mirror with Change Volumes |
HU00473 |
SVC |
High Importance
|
SVC DH8 node reports node error 522 following system board replacement
(show details)
Symptom |
None |
Environment |
SVC DH8 model nodes |
Trigger |
Following replacement of system board |
Workaround |
None |
|
7.3.0.8 |
|
HU00481 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart when new multi-tier storage pool is added and an MDisk overload condition is detected within the first day
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems running v7.3 or later with EasyTier enabled |
Trigger |
If SSD capcaity is fully utilised by volume creation/expansion or migration when EasyTier enabled |
Workaround |
None |
|
7.3.0.8 |
EasyTier |
HU00493 |
SVC |
High Importance
|
SVC DH8 node offline due to battery backplane problem
(show details)
Symptom |
Loss of Redundancy |
Environment |
SVC DH8 model nodes |
Trigger |
AC power loss |
Workaround |
None |
|
7.3.0.8 |
|
HU00502 |
SVC, V7000, V5000, V3700 |
High Importance
|
EasyTier migration running at a reduced rate
(show details)
Symptom |
Performance |
Environment |
Systems running v7.3 or later with EasyTier enabled |
Trigger |
None |
Workaround |
None |
|
7.3.0.8 |
EasyTier |
HU00506 |
All |
High Importance
|
Increased destaging latency in upper cache when using v7.3.0 release
(show details)
Symptom |
Performance |
Environment |
Systems running v7.3 |
Trigger |
Specific I/O workloads |
Workaround |
None |
|
7.3.0.8 |
|
HU00519 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart due to FlashCopy deadlock condition
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems using FlashCopy |
Trigger |
Starting and stopping a FlashCopy mapping |
Workaround |
None |
|
7.3.0.8 |
FlashCopy |
HU00529 |
SVC, V7000 |
High Importance
|
Increased latency on SVC and V7000 systems running v7.3 (excluding DH8 & V7000 Gen2 models) when using compressed volumes due to defragmentation issue
(show details)
Symptom |
Performance |
Environment |
Systems with compressed volumes |
Trigger |
Upgrade from v7.2.0 to v7.3.0 on systems with SVC CG8 or V7000 Generation 1 model nodes |
Workaround |
None |
|
7.3.0.8 |
Compression |
IC90799 |
All |
High Importance
|
Node warmstart when drive medium error detected at the same time as drive is changing state to offline
(show details)
Symptom |
Single Node Warmstart |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.8 |
|
IT03354 |
All |
High Importance
|
Poor read performance with iSCSI single threaded read workload
(show details)
Symptom |
Performance |
Environment |
Systems using iSCSI connected hosts |
Trigger |
Single threaded read workload where the I/O size is not to the power of 2 |
Workaround |
Disable TCP delayedack at the host interface |
|
7.3.0.8 |
iSCSI |
IT04105 |
SVC, V7000, V5000, V3700 |
High Importance
|
EasyTier does not promote extents between different tiers when using release v7.3.0
(show details)
Symptom |
Performance |
Environment |
Systems running v7.3 or later with EasyTier enabled |
Trigger |
None |
Workaround |
Add small sized MDisks from different tiers to separate pools which do not have mulit-tier storage |
|
7.3.0.8 |
EasyTier |
HU00468 |
V7000, V5000, V3700, V3500 |
Suggested
|
Drive firmware task not removed from GUI running tasks display following completion of drive firmware update action
(show details)
Symptom |
None |
Environment |
Systems running v7.3 or later |
Trigger |
Drive firmware update |
Workaround |
Issue a new applydrivesoftware command to a drive that does not exist |
|
7.3.0.8 |
Graphical User Interface |
HU00485 |
All |
Suggested
|
TPC cache statistics inaccurate or unavailable in v7.3.0 and later release
(show details)
Symptom |
None |
Environment |
Environments using IBM TPC |
Trigger |
None |
Workaround |
None |
|
7.3.0.8 |
System Monitoring |
HU00497 |
SVC, V7000 |
HIPER
|
Volumes offline due to incorrectly compressed data. Second fix for issue. For more details refer to this Flash
(show details)
Symptom |
Offline Volumes |
Environment |
Systems using compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.6 |
Compression |
HU00277 |
SVC, V7000, V5000, V3700 |
HIPER
|
Loss of access to data when adding a Global Mirror Change volume if the system is almost out of FlashCopy bitmap space
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems using Global Mirror with Change Volumes |
Trigger |
None |
Workaround |
Use the 'chiogrp -feature flash -size' command to change the bitmap space |
|
7.3.0.5 |
Global Mirror with Change Volumes |
HU00464 |
All |
HIPER
|
Loss of access to data due to resource leak in v7.3.0
(show details)
Symptom |
Loss of Access to Data |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.5 |
Cache |
HU00496 |
SVC, V7000 |
HIPER
|
SVC volumes offline and data unrecoverable. For more details refer to this Flash
(show details)
Symptom |
Data Integrity Loss |
Environment |
Systems running v7.3.0.0 - v7.3.0.4 with compression accelerator hardware and compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.5 |
Compression |
HU00280 |
SVC, V7000, V5000, V3700 |
Critical
|
Multiple node warmstarts triggered by a Global Mirror disconnection
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems using Global Mirror |
Trigger |
None |
Workaround |
None |
|
7.3.0.5 |
Global Mirror |
HU00444 |
SVC, V7000 |
Critical
|
Node warmstarts due to overloaded compression engine
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems with compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.5 |
Compression |
HU00450 |
SVC, V7000, V5000, V3700 |
Critical
|
Manual upgrade with stopped Global Mirror relationships can not complete non-disruptively due to dependent volumes
(show details)
Symptom |
None |
Environment |
Systems using Global Mirror |
Trigger |
Manual (paced) upgrade |
Workaround |
Perform automatic upgrade instead if manual upgrade |
|
7.3.0.5 |
Global Mirror |
HU00176 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart due to a I/O deadlock when using FlashCopy
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems using FlashCopy |
Trigger |
Flashcopy |
Workaround |
None |
|
7.3.0.5 |
FlashCopy |
HU00274 |
SVC, V7000, V5000, V3700 |
High Importance
|
Quiesce and resume of host I/O when Global Mirror consistency group reaches consistent_synchronized state
(show details)
Symptom |
Performance |
Environment |
Systems using Global Mirror |
Trigger |
None |
Workaround |
None |
|
7.3.0.5 |
Global Mirror |
HU00422 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart when using Global Mirror Change Volumes
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems using Global Mirror with Change Volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.5 |
Global Mirror with Change Volumes |
HU00443 |
SVC, V7000, V5000, V3700 |
High Importance
|
Global Mirror Change Volumes stops replicating after an upgrade from V641 to v7.2.0 or later
(show details)
Symptom |
None |
Environment |
Systems using Global Mirror with Change Volumes |
Trigger |
Following upgrade to v7.2.0 or later |
Workaround |
None |
|
7.3.0.5 |
Global Mirror with Change Volumes |
HU00446 |
All |
High Importance
|
v7.3.0 cache does not make effective use of CPU resources Note: A restart is required to activate this fix if you upgrade from an earlier version of v7.3.0
(show details)
Symptom |
Performance |
Environment |
All systems running v7.3 or later |
Trigger |
None |
Workaround |
None |
|
7.3.0.5 |
Cache |
HU00462 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart when using Easytier with a single tier in a pool on v7.3
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems running v7.3 or later with EasyTier enabled |
Trigger |
Using EasyTier with single tier in a storage pool |
Workaround |
Turn off EasyTier |
|
7.3.0.5 |
EasyTier |
HU00465 |
SVC |
High Importance
|
Node error 581 on 2145-CF8 nodes due to problem communicating with the IMM
(show details)
Symptom |
Loss of Redundancy |
Environment |
SVC systems with CF8 model nodes |
Trigger |
During upgrade to 730 code stream |
Workaround |
If node gets stuck with 581 node error, reboot the node and apply standard stalled upgrade procedure if this occurs on upgrade to V730 |
|
7.3.0.5 |
System Update |
HU00486 |
SVC |
High Importance
|
Systems upgraded to 2145-DH8 nodes do not make use of the compression acceleration cards for compressed volumes
(show details)
Symptom |
Performance |
Environment |
SVC systems using DH8 model nodes and compressed volumes |
Trigger |
Upgrade from SVC CG8 to DH8 model nodes |
Workaround |
None |
|
7.3.0.5 |
Compression |
IC90374 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart due to a I/O deadlock when using FlashCopy functions
(show details)
Symptom |
Single Node Warmstart |
Environment |
All |
Trigger |
Flashcopy |
Workaround |
None |
|
7.3.0.5 |
FlashCopy |
HU00354 |
SVC, V7000, V5000 |
Critical
|
Loss of access to data if upgrading directly from 6.4.x to v7.3.0.1, v7.3.0.2 or v7.3.0.3 with multiple access I/O groups configured on any volume
(show details)
Symptom |
Loss of Access to Data |
Environment |
Systems with more than one I/O group |
Trigger |
Systems that are upgraded from V6.4.0 to v7.3.0 or later with volumes that have access configured through more than one I/O group |
Workaround |
Ensure that no volumes in the system to be upgraded are accessible through more than one I/O group. This can be checked using the 'lsvdiskaccess' cli command |
|
7.3.0.4 |
Hosts |
HU00432 |
All |
High Importance
|
Performance reduction and node warmstarts when running out of cache resources in v7.3.0.1, v7.3.0.2, or v7.3.0.3
(show details)
Symptom |
Single Node Warmstart |
Environment |
All systems running v7.3 or later |
Trigger |
None |
Workaround |
A possible workaround is to cache disable any volumes that are hitting the timouts |
|
7.3.0.4 |
Cache |
HU00324 |
SVC, V7000 |
Critical
|
Compressed volumes offline after upgrading to v7.3.0.1 or v7.3.0.2
(show details)
Symptom |
Offline Volumes |
Environment |
Systems running v7.3.0.1 with compressed volumes |
Trigger |
Upgrade to v7.3.0.1 |
Workaround |
None |
|
7.3.0.3 |
Compression |
HU00296 |
SVC, V7000 |
High Importance
|
Node warmstart when handling specific compression workloads
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.3 |
Compression |
HU00336 |
All |
High Importance
|
Single node warmstart when volumes go offline on systems running v7.3.0.0, v7.3.0.1 or v7.3.0.2
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems running v7.3.0.0, v7.3.0.1 or v7.3.0.2 |
Trigger |
Offline volume condition |
Workaround |
None |
|
7.3.0.3 |
Cache |
HU00304 |
V5000, V3700, V3500 |
Suggested
|
Both node canister fault LEDs are set to ON following upgrade to v7.3 release
(show details)
Symptom |
None |
Environment |
V5000,V3700 & V3500 Systems |
Trigger |
Update to v7.3.0 |
Workaround |
None |
|
7.3.0.3 |
System Monitoring |
HU00302 |
All |
Critical
|
Multiple repeating node warmstarts if system has previously run a code release earlier than 6.4.0 and is upgraded to v7.3.0.1 without stepping through a 6.4.x release
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems running v7.3.0.1 |
Trigger |
Upgrade to v7.3.0.1 |
Workaround |
None |
|
7.3.0.2 |
Reliability Availability Serviceability |
HU00014 |
All |
Critical
|
Multiple node warmstarts if many volume-host mappings exist to a single host
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
All |
Trigger |
Large number of hosts mapped to the same volumes |
Workaround |
None |
|
7.3.0.1 |
Hosts |
HU00133 |
V7000, V5000, V3700, V3500 |
Critical
|
Loss of access to data when an enclosure goes offline during software upgrade
(show details)
Symptom |
Loss of Access to Data |
Environment |
All |
Trigger |
Storwize code update |
Workaround |
None |
|
7.3.0.1 |
Reliability Availability Serviceability |
HU00195 |
SVC, V7000 |
Critical
|
Multiple node warmstarts when creating the first compressed volume in an I/O group
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems with compressed volumes |
Trigger |
Creation of first compressed volume in an I/O group |
Workaround |
None |
|
7.3.0.1 |
Compression |
HU00283 |
SVC, V7000 |
Critical
|
Multiple node warmstarts caused by invalid compressed volume metadata
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems with compressed volumes |
Trigger |
None |
Workaround |
None |
|
7.3.0.1 |
Compression |
HU00287 |
All |
Critical
|
Multiple node warmstarts when using hosts where the IQN is the same, but uses different capitalisation
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems with iSCSI connected hosts |
Trigger |
Duplicate IQN detected |
Workaround |
Ensure all hosts have unique IQN's |
|
7.3.0.1 |
iSCSI |
HU00298 |
SVC, V7000, V5000 |
Critical
|
Multiple node warmstarts when using IBM DS4000 using an incorrect host type
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems virtualising IBM DS4000 controllers |
Trigger |
IBM DS4000 using an incorrect host type |
Workaround |
None |
|
7.3.0.1 |
Storage Virtualisation |
IC92665 |
All |
Critical
|
Multiple node warmstarts caused by iSCSI initiator using the same IQN as SVC or Storwize
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems with iSCSI connected hosts |
Trigger |
Creation of duplicate IQN |
Workaround |
Ensure all hosts have unique IQN's |
|
7.3.0.1 |
iSCSI |
IT01250 |
V7000, V5000, V3700, V3500 |
Critical
|
Loss of access to data when node or node canister goes offline during drive update
(show details)
Symptom |
Loss of Access to Data |
Environment |
All |
Trigger |
Drive firmware update |
Workaround |
None |
|
7.3.0.1 |
Reliability Availability Serviceability |
HU00017 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart after failed mkrcpartnership command
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems using Metro Mirror or Global Mirror |
Trigger |
When running mkrcrelationship command |
Workaround |
Ensure that RC commands are not issued on multiple clusters simultaneously, and if a mkrcrelationship command fails, ensure a different RC command is run successfully on the same cluster, before running an RC command on any (directly or indirectly) partnered cluster |
|
7.3.0.1 |
Global Mirror, Global Mirror with Change Volumes, Metro Mirror |
HU00026 |
SVC, V7000 |
High Importance
|
Node warmstart after all compressed volumes in an I/O group are deleted
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with compressed volumes |
Trigger |
When deleting all compressed volumes in an I/O group |
Workaround |
Avoid deleting all compressed volumes in an I/O group |
|
7.3.0.1 |
Compression |
HU00219 |
All |
High Importance
|
Node warmstart when stopping a FlashCopy map in a chain of FlashCopy mappings
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems using FlashCopy |
Trigger |
Stopping a FlashCopy map in a chain of FlashCopy mappings |
Workaround |
Do not remove FlashCopy maps |
|
7.3.0.1 |
FlashCopy |
HU00253 |
SVC, V7000, V5000, V3700 |
High Importance
|
Global Mirror with Change Volumes does not resume copying after an I/O group goes offline at secondary cluster
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems using Global Mirror with Change Volumes |
Trigger |
I/O group goes offline at secondary cluster |
Workaround |
Stopping and restarting the relationship will fix the state |
|
7.3.0.1 |
Global Mirror with Change Volumes |
HU00257 |
SVC, V7000, V5000 |
High Importance
|
Multiple node warmstarts when EMC RecoverPoint appliance restarted
(show details)
Symptom |
Multiple Node Warmstarts |
Environment |
Systems virtualising EMC Recover Point controllers |
Trigger |
Restart of backend EMC Recover Point device |
Workaround |
None |
|
7.3.0.1 |
Storage Virtualisation |
HU00291 |
SVC, V7000, V5000, V3700 |
High Importance
|
Node warmstart caused by instability in IP replication connection
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems using IP replication |
Trigger |
Instability in link used by IP replication |
Workaround |
None |
|
7.3.0.1 |
IP Replication |
HU00293 |
V7000, V5000, V3700, V3500 |
High Importance
|
Node canister fails to boot after hard shutdown
(show details)
Symptom |
Loss of Redundancy |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.1 |
Reliability Availability Serviceability |
IC89562 |
All |
High Importance
|
Node warmstart when handling a large number of XCOPY commands
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with hosts using XCOPY function |
Trigger |
Host XCOPY commands |
Workaround |
None |
|
7.3.0.1 |
Hosts |
IC89608 |
All |
High Importance
|
Node warmstart when handling a large number of XCOPY commands
(show details)
Symptom |
Single Node Warmstart |
Environment |
Systems with hosts using XCOPY function |
Trigger |
If a volume goes offline whist there are in flight XCOPY commands |
Workaround |
None |
|
7.3.0.1 |
Hosts |
HU00183 |
SVC |
Suggested
|
GUI becomes non-responsive on larger configurations
(show details)
Symptom |
None |
Environment |
SVC systems using CG8 "Chubby" model nodes |
Trigger |
None |
Workaround |
Restart Tomcat service |
|
7.3.0.1 |
Graphical User Interface |
HU00236 |
V7000, V5000, V3700, V3500 |
Suggested
|
Performance degradation when changing the state of certain LEDs
(show details)
Symptom |
Performance |
Environment |
All |
Trigger |
Running of the following commands: chenclosurecanister -clearswap chenclosurecanister -identify chenclosurecanister -excludesasport chenclosureslot -exclude chenclosureslot -identify |
Workaround |
Do not use the chenclosurecanister or chenclosureslot commands unless required |
|
7.3.0.1 |
Reliability Availability Serviceability |
HU00241 |
All |
Suggested
|
Unresponsive GUI caused by locked IPC sockets
(show details)
Symptom |
None |
Environment |
All |
Trigger |
None |
Workaround |
Reboot configuration node |
|
7.3.0.1 |
Graphical User Interface |
HU00272 |
All |
Suggested
|
Arrays incorrectly reporting resync progress as 0% or 255%
(show details)
Symptom |
None |
Environment |
All |
Trigger |
Update to v7.2.0 |
Workaround |
None |
|
7.3.0.1 |
Backend Storage |
HU00288 |
All |
Suggested
|
GUI does not remember the most recently visited page
(show details)
Symptom |
None |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.1 |
Graphical User Interface |
HU00290 |
V7000 |
Suggested
|
System incorrectly attempts to upgrade firmware during maintenance discharge
(show details)
Symptom |
None |
Environment |
V7000 Generation 1 systems |
Trigger |
Battery firmware update |
Workaround |
None |
|
7.3.0.1 |
Reliability Availability Serviceability |
HU00294 |
All |
Suggested
|
Event ID 981007 not always logged correctly
(show details)
Symptom |
None |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.1 |
System Monitoring |
IC92993 |
All |
Suggested
|
Fix Procedure for 1686 not replacing drive correctly
(show details)
Symptom |
Loss of Redundancy |
Environment |
All |
Trigger |
Disk drive failure |
Workaround |
None |
|
7.3.0.1 |
GUI Fix Procedure |
IC94781 |
All |
Suggested
|
GUI Health status pod still showing red after offline node condition has been recovered
(show details)
Symptom |
None |
Environment |
All |
Trigger |
None |
Workaround |
None |
|
7.3.0.1 |
Graphical User Interface |