| Automatically map SCSI devices |
Checked (enabled) |
| Query name server for all N-ports |
Checked (enabled) |
| Allow multiple paths to SCSI targets |
Checked (enabled) |
| Point-to-point |
- Checked for fabric attach
- Arbitrated loop for direct attach
|
| Register for state change |
Checked (enabled) |
| Use report LUNs |
Checked (enabled) |
| Use name server after RSCN |
Checked (enabled) |
| LUN mapping |
Checked (enabled) |
| Automatic LUN mapping |
Checked (enabled) |
| Scan in device ID order |
Not checked (disabled) |
| Enable class 2 for SCSI devices |
Not checked (disabled) |
| Report unknown SCSI devices |
Not checked (disabled) |
| Look for disappearing devices |
Not checked (disabled) |
| Translate queue full to busy |
Checked (enabled) |
| Use bus reset status for retries |
Not checked (disabled) |
| Retry unit attention |
Not checked (disabled) |
| Retry PLOGI open failures |
Not checked (disabled) |
| Maximum number of LUNs |
Equal to or greater than the number of the
SAN Volume Controller LUNs available to the host bus adapter |
| Maximum queue depth |
8 |
| Link Timer |
30 seconds |
| Retries |
64 |
| E_D_TOV |
2000 milliseconds |
| AL_TOV |
15 milliseconds |
| Wait ready timer |
45 seconds |
| Retry timer |
2000 milliseconds |
| R_A_TOV |
2 seconds |
| ARB_TOV |
1000 milliseconds |
| Link Control |
| Topology |
Point-to-point (fabric) |
| Link speed |
Auto |