Switch zoning limitations for the EMC Symmetrix Configuring the EMC Symmetrix Quorum disks on EMC Symmetrix

This topic discusses the supported topologies relative to switch zoning and connection to the SAN.

Switch zoning

The SAN Volume Controller switch zone must include at least one target port on two or more fibre-channel adapters (FAs) in order to have no single point of failure.

Connecting to the SAN

The Symmetrix connects to the SAN via a fibre-channel director. Directors are installed in pairs and each consists of two boards, one of which is a fibre-channel adapter (FA). The FA provides 2 - 12 target ports. Symmetrix assigns a WWNN per target port and SAN Volume Controller can resolve up to four WWNN's per subsystem. In order to connect more than four target ports to a SAN Volume Controller, the following procedure must be performed:

  1. Divide the set of target ports into groups of 2 - 4.
  2. Define a discrete set of logical units for each group.
  3. Map the logical units to each target port in their group.

The SAN Volume Controller views each group of target ports as a separate subsystem. Ensure that no LUs are a member of more than one group.

Related topics Configuring the EMC Symmetrix Quorum disks on EMC Symmetrix

(C) Copyright International Business Machines Corporation 2003, 2004