This topic discusses the supported topologies relative to switch zoning and connection to the SAN.
The SAN Volume Controller switch zone must include at least one target port on two or more fibre-channel adapters (FAs) in order to have no single point of failure.
The Symmetrix connects to the SAN via a fibre-channel director. Directors are installed in pairs and each consists of two boards, one of which is a fibre-channel adapter (FA). The FA provides 2 - 12 target ports. Symmetrix assigns a WWNN per target port and SAN Volume Controller can resolve up to four WWNN's per subsystem. In order to connect more than four target ports to a SAN Volume Controller, the following procedure must be performed:
The SAN Volume Controller views each group of target ports as a separate subsystem. Ensure that no LUs are a member of more than one group.