Sharing the EMC Symmetrix controller between
a host and the SAN Volume Controller
The EMC Symmetrix can
be shared between a host and a SAN Volume Controller. This topic briefly discusses the restrictions.
- Target ports must not be shared between the SAN Volume Controller and other hosts.
- A single host must not be connected to a SAN Volume Controller and a Symmetrix because
the multi-pathing drivers (for example, Subsystem Device Driver (SDD)), do
not co-exist.
- Other hosts may be connected directly to Symmetrix at the same time as SAN Volume Controller,
under the following conditions:
- The fabric must be zoned such that other hosts cannot access the target
ports used by the SAN Volume Controller.
- Symmetrix must be configured such that other hosts cannot access the LUs
that are managed by the SAN Volume Controller.