SAN problem determination Troubleshooting Recovering from a Disruptive Software Upgrade

The procedures to service the SAN Volume Controller that are provided in this chapter help you solve problems on the SAN Volume Controller and its connection to the storage area network.

Context

SAN failures might cause the SAN Volume Controller cluster to be unable to form or they might cause SAN Volume Controller disks to be inaccessible to host systems. Failures can be caused by SAN configuration changes or by hardware failures in SAN components.

Steps

If you were sent here from the Maintenance Analysis Procedures or error codes in this chapter, then perform the following steps:

  1. If the customer has changed the SAN configuration by changing the fibre-channel cable connections or switch zoning, ask the customer to verify that the changes were correct and, if necessary, reverse those changes.
  2. Verify that the power is turned on to all switches and RAID controllers that the SAN Volume Controller uses, and that they are not reporting any hardware failures. If problems are found, resolve those problems before proceeding further.
  3. Verify that the fibre-channel cables that connect the SAN Volume Controllers to the switches are securely connected.
  4. If the customer is running a SAN management tool that you are familiar with and that you have access to, use that tool to view the SAN topology and isolate the failing component. If the customer is not using any other SAN management tool, start Tivoli SAN Manager (TSanM) on the master console and use that tool to view the SAN topology and isolate the failure. For details of performing SAN problem determination with TSanM, contact the Tivoli Storage Area Network (SAN) support center.
Related topics Troubleshooting Recovering from a Disruptive Software Upgrade

(C) Copyright International Business Machines Corporation 2003, 2004