When you turn on the SAN Volume Controller, the system board performs self tests. During the initial tests the hardware boot symbol displays.
If a critical failure is detected during the tests, the SAN Volume Controller software is not loaded and no additional fault information is provided. When the SAN Volume Controller software is loaded, additional testing is performed. This testing ensures that all the required hardware and software components are installed and functioning correctly. During this portion of the testing, the word Booting displays on the front panel along with a boot progress code and a progress bar.
If a test fails the word Failed displays on the front panel. You can use the progress code to isolate the cause of the problem. If the Booting progress bar fails to move to the right for two minutes, the test process is hung. Use the boot progress code to isolate the failure.
The service controller performs internal checks. The service controller is vital to the operation of the SAN Volume Controller. When an internal check fails, the SAN Volume Controller does not operate. Ignore other front panel indicators when you see that the Check LED is illuminated.
| Note: The check LED stays lit when you program the microcode on the service controller, so it is not an indication that there is a problem. |
The uninterruptible power supply also performs internal tests. If the uninterruptible power supply is capable of reporting the failure condition, the SAN Volume Controller displays critical failure information on the front panel display or sends noncritical failure information to the SAN Volume Controller cluster error log. If the SAN Volume Controller cannot communicate with the uninterruptible power supply, it displays a boot failure error message on the front panel display. Further problem determination information might also be displayed on the front panel of the uninterruptible power supply.