You can change the speed of the fibre-channel ports on a SAN Volume Controller through the front panel on the SAN Volume Controller node or by a command sent to a SAN Volume Controller cluster using the Ethernet interface.
All fibre-channel ports and nodes on a SAN Volume Controller must operate at the same speed. The default for the port speed is 2Gb per second. If the fibre-channel fabric is using fibre-channel switches that are unable to operate at 2Gb per second, set the SAN Volume Controller fibre-channel port speed to 1Gb per second during the installation procedure. If you must replace a 2Gb per second fibre-channel switch with a 1Gb fibre-channel switch, you must manually switch the SAN Volume Controller fibre-channel port speed before you can use the SAN Volume Controller at 1Gb per second.
If a new SAN Volume Controller node is being added to an existing SAN Volume Controller configuration you only need to change the speed setting if the switch is only capable of running at 1Gb per second. If the SAN Volume Controller internal disk drive fails, the fibre-channel speed setting is lost, but the Node Rescue Procedure that you use to restore the SAN Volume Controller software automatically selects the correct speed. If a 1Gb per second fibre-channel switch is being replaced by a 2Gb per second fibre-channel switch, the existing SAN Volume Controller clusters operate at 1Gb per second. You can switch to 2Gb per second any time using the command-line interface.