Checking the status of the node ports Nodes Viewing port details

You can check the status of the node ports by using the SAN Volume Controller user interface or by using the command-line interface.

Figure 121 shows what is displayed when you type the following command:

svcinfo lsnode -delim : nodename

Example

Figure 121. Example of what is displayed when you check the status of the node port
id:1
name:node1
UPS_serial_number:10L3ANP
WWNN:5005676801000013
status:online
IO group id:0
IO group name:io_grp0
partner node id:2
partner node name:node2
config node:yes
UPS_unique_id:202378101C0D17A0
port id:5005676801100013
port status:active
port id:5005676801200013
port status:active
port id:5005676801300013
port status:active
port id:5005676801400013
port status:active

Figure 121 shows information for the named node on line two of the example. You can see the port ID and the status of the port in the last eight lines of the example. In this example, the last eight lines show a port status of active. Other status you might see include not installed, failed, or inactive.

For more information about using the command-line interface, see IBM TotalStorage Open Software Family SAN Volume Controller Command-line Interface User's Guide.

(C) Copyright International Business Machines Corporation 2003, 2004