The SAN fabric can be arranged
with various zones to allow the SAN Volume Controllers to
access the RAID controllers and to allow the host systems to access the SAN Volume Controllers. The hosts should not directly access
or operate on the RAID controllers.
- Install and configure your switches to create the zones that the SAN Volume Controller needs. You must create at least
two general zones.
- Each host (or partition of a host) may have between one and four FC ports.
- Switch zoning should be used to ensure that each host
FC port is zoned to exactly one FC port of each SAN Volume Controller node in the cluster.
For hosts with multiple FC ports, IBM recommends that
each FC port of a host is zoned with a different group of SAN Volume Controller
ports.
IBM recommends that the subsystem workload to each SAN Volume Controller port should be
equal. This will typically involve zoning roughly the same number of host
FC ports to each SAN Volume Controller FC port.
IBM recommends that you manually set the domain IDs prior to building the
multiswitch fabric and prior to zoning. There are several reasons for doing
this:
- When two switches are joined while active, they will determine if the
domain ID is already in use as before, however, if there is a conflict
it cannot be changed in an active switch. This conflict will cause the fabric
merging process to fail.
- The domain ID is used to identify switch ports when zoning is implemented
using the domain and switch port number. If domain ID's are negotiated at
every fabric start up, there is no guarantee that the same switch will have
the same ID the next time; therefore, any zoning definitions may become invalid.
- If the domain ID is changed after a SAN is set up, some host systems may
have difficulty logging back in with the switch, and a host reconfiguration
may be required to detect devices on the switch.