This task provides step-by-step instructions for replacing a faulty node in the cluster using the command-line interface (CLI).
Before you attempt to replace a faulty node with a spare node you must ensure that:
Perform the following steps to display and record the WWNN of the spare node:
If a node fails, the cluster continues to operate with degraded performance, until the faulty node is repaired. If the repair operation is likely to take an unacceptable amount of time, it might be useful to replace the faulty node with a spare node. However, the appropriate procedures must be followed and precautions must be taken, in order not to interrupt I/O operations and to avoid compromising the integrity of your data. The procedures outlined in this topic involve changing the worldwide node name (WWNN) of a SAN Volume Controller. These procedures must be followed with care in order to avoid duplicate WWPNs which can cause data corruption.
Be aware that by performing these procedures the following changes will be made to your configuration:
WWNN 50050768010000F6 WWNN displayed on front panel 000F6 WWPN Port 1 50050768014000F6 WWPN Port 2 50050768013000F6 WWPN Port 3 50050768011000F6 WWPN Port 4 50050768012000F6
Perform the following steps to replace a faulty node in the cluster:
Perform the following steps to verify the name and ID:
If the node was faulty it will be shown as offline. Ensure the partner node in the I/O group is online.
If you are replacing the node for other reasons, determine the node you wish to replace and again ensure the partner node in the I/O group is online.
The faulty node will be offline.
Important: Do not plug the fibre-channel cables into the spare node until spare node has been configured with the WWNN from the faulty node.
| Note: The signal cable can be plugged into any vacant position on the top row of serial connectors on the UPS. If no spare serial connectors are available on the UPS, disconnect the cables from the faulty SAN Volume Controller. |
Perform the following steps to change the WWNN of the spare node so that it matches the WWNN of the faulty node:
| Note: To edit the displayed number use the Up and Down buttons to increase or decrease the numbers displayed. Use the Left and Right buttons to move between fields. When the five characters match the number recorded in step 1, press the Select button twice to accept the number. |
Remember: Record the following information:
This can avoid a possible data corruption exposure when the node is re-added to the cluster.
| Attention: When the faulty node is repaired do not connect the fibre-channel cables to it. Connecting the cables might cause data corruption. |
| Note: To edit the displayed number use the Up and Down buttons to increase or decrease the numbers displayed. Use the Left and Right buttons to move between fields. |
This SAN Volume Controller can now be used as a spare node.
| Attention: Never connect a SAN Volume Controller with a WWNN of 00000 to the cluster. If this SAN Volume Controller is no longer required as a spare and is to be used for normal attachment to a cluster you must first use the procedure described at to change the WWNN to the number you recorded when a spare was created. Using any other number might cause data corruption. |