Removing the service controller from the SAN Volume Controller Removing parts Removing the service controller cables

The following task describes how to remove the service controller from the SAN Volume Controller.

Note:Note: If you are replacing the service controller as part of a problem determination procedure, you must also replace the cables that are supplied as part of the service controller FRU.
Steps

Perform the following steps to remove the service controller:

  1. Refer to Figure 131.
    Figure 131. Removing the service controller
    Removing the service controller
  2. Remove all power from the SAN Volume Controller.
  3. Remove the SAN Volume Controller from the rack.
  4. Remove the top cover of the SAN Volume Controller.
  5. Remove the front panel of the SAN Volume Controller.
  6. Attention: Remove the service controller carefully to avoid damage to the attached cables.

    Pull the two handles  2  to release the latches, and carefully pull the service controller out of the SAN Volume Controller.

  7. Remove the service controller  1 .
  8. If you have any other tasks to do inside the SAN Volume Controller, do those tasks now. Otherwise, reinstall the service controller.
    Notes:
    Notes:
    1. The 40-way cable connector is keyed.
    2. Before you reconnect the ribbon cable, ensure that its contacts are downward. CAREFULLY install the cable to the rear of the service controller being sure to install the cable straight in with no rocking or twisting during installation. Be sure to verify that the dark blue line on the cable connector ends is not visible. This ensures that the cable is fully seated. See Figure 132 and Figure 133.
      Figure 132. Service Controller card cable installed properly
      Service Controller card cable installed properly
      Figure 133. Service Controller card cable not properly seated
      Service Controller card cable not properly seated
    3. When you install the service controller, ensure that the cables do not come into contact with the fan assembly that is mounted behind the service controller bay. Fold the cables under the service controller as you push the service controller into the SAN Volume Controller. Keep pushing the service controller until the latches click home.
    4. From the inside of the SAN Volume Controller, ensure that the cables are correctly attached to the service controller.
  9. Reinstall other parts in the reverse sequence.
    Note:Note: The WWPNs of the fibre-channel ports are derived from the WWNN of the service controller. If you do not perform step 10, you must restart the host systems before they are able to access disks through this SAN Volume Controller.
  10. If a service controller is replaced as part of concurrent maintenance, it is necessary to re-write the WWNN on the new service controller. Failure to do so will mean that the host systems will not be able to access the fibre channel ports on that node until the host systems are rebooted. To restore the WWNN do the following:
    1. Power-on the SAN Volume Controller
    2. Display the node status on the service panel. Refer to the procedure for displaying node status on the service panel.
    3. Press and hold the down button; press and release the select button; release the down button.
    4. The WWNN is displayed on Line 1 of the display; line 2 of the display contains the last five characters of the original WWNN. If the number displayed is all zeros, this is probably because you have also replaced the disk drive as part of this repair operation.
      1. If all zeros are displayed go to step 10e.
      2. If any other number is displayed, press the select button to accept the number. The WWNN is restored.
    5. If the number displayed is all zeros, display the World Wide Node Name in the VPD for the node that you are working on. Record the last five characters of the number.
    6. With the World Wide Node Name (WWNN) displayed on the service panel, press and hold the down button, press and release the select button, release the down button. Edit the displayed number using the up and down buttons to increase or decrease the numbers displayed. Use the left and right buttons to move between fields. When the number that you noted from the VPD is displayed, press the select button twice to accept the number. The WWNN is restored.
Related topics Removing parts Removing the service controller cables

(C) Copyright International Business Machines Corporation 2003, 2004