Registering the SAN Volume Controller Ports with your EMC CLARiiON Configuring the EMC CLARiiON controller with Access Logix installed Configuring your storage groups

This task provides step-by-step instructions for registering SAN Volume Controller ports with an EMC CLARiiON controller that has Access Logix installed.

Prerequisites

At this point, the EMC CLARiiON controller is not connected to the SAN Volume Controller. Assume you already have a RAID controller with logical units (LUs) and you've identified which LUs will be presented to the SAN Volume Controller.

Steps

Perform the following steps to register SVC ports with the EMC CLARiiON controller:

  1. From the Enterprise Storage window, right-click on the storage subsystem.
  2. Select Connectivity Status. The Connectivity Status window is displayed.
  3. Click New. The Create Initiator Record window is displayed.
  4. Fill in the HBA WWN field. You must know the following information (see "Adding nodes to the cluster using the CLI"):
    • WWNN of each SAN Volume Controller in the cluster
    • WWPN of each port ID for each node on the cluster
    The HBA WWN field is made up of the WWNN and the WWPN for the SAN Volume Controller port. The following output shows an example: 50:05:07:68:01:00:8B:D8:50:05:07:68:01:20:8B:D8
  5. Select A in the field marked SP and 0 in the SP Port field.
  6. For the Initiator Type field, select Clariion Open in the drop down list.
  7. Deselect the ArrayCommPath checkbox if it has been selected.
  8. Select 2 from the Failover Mode field drop down list.
  9. Assign a host name in the Host Name field.
    Notes:
    Notes:
    1. If this is the first time that a port has been registered, ensure that you select the New Host option. Otherwise, select Existing Host.
    2. Ensure that the same host name is entered for each port that is registered.
  10. Click OK.
  11. Perform step 5 for all possible combinations. The following example shows the different combinations of a subsystem with four ports:
    • SP: A SP Port: 0
    • SP: A SP Port: 1
    • SP: B SP Port: 0
    • SP: B SP Port: 1
  12. Refer to steps 1 through 11 to register the rest of your SAN Volume Controller WWPNs.
Result

All your WWPNs are registered against the host name that you specified.

Related topics Configuring the EMC CLARiiON controller with Access Logix installed Configuring your storage groups

(C) Copyright International Business Machines Corporation 2003, 2004