RAID array configuration Configuration guidelines Optimal managed disk group configurations

This topic provides overview information about RAID array configurations.

Overview

When using virtualization, ensure that the storage devices are configured to provide some type of redundancy against hard disk failures. A failure of a storage device can affect a larger amount of storage being presented to the hosts. To provide redundancy, storage devices should be configured as RAID arrays which use either mirroring or parity to protect against single failures.

When creating RAID arrays with parity protection (for example, RAID-5 arrays) consider how many component disks you want to use in each array. The larger the number of disks, the fewer disks are required to provide availability for the same total capacity (1 per array). However, more disks means a longer time is taken to rebuild a replacement disk after a disk failure, and during this period a second disk failure will cause a loss of all array data. More data is affected by a disk failure for a larger number of member disks resulting in reduced performance while rebuilding onto a hot spare and more data being exposed if a second disk fails before the rebuild has completed. The smaller the number of disks, the more likely it is that write operations span an entire stripe (strip size x number of members minus one). In this case, write performance is improved. The number of disk drives required to provide availability may be unacceptable if arrays are too small.

Notes:
Notes:
  1. If in doubt, arrays with between 6 and 8 member disks is recommended.
  2. When creating RAID arrays with mirroring, the number of component disks in each array does not affect redundancy or performance.
Related topics Configuration guidelines Optimal managed disk group configurations

(C) Copyright International Business Machines Corporation 2003, 2004