Preparing your SAN Volume Controller environment Installation planning Preparing your uninterruptible power supplyinternal battery backup environment

This topic provides information you need to ensure that your physical site meets the installation requirements for the SAN Volume Controller.

Dimensions and weight
Height Width Depth
Approximate
Maximum
Weight
43 mm

(1.7 in.)

440 mm

(17.3 in.)

660 mm

(26 in.)

12.7 kg

(28 lb.)

Additional space requirements

Location Additional space required Reason
Left- and right-hand sides 50 mm (2 in.) Cooling air flow
Back 100 mm (4 in.) minimum Cable exit
AC input-voltage requirements

Power Supply Assembly Type Voltage Frequency
220 V
88 to 264 V ac
47 to 63 Hz

 

Environment

Environment Temperature Altitude
Relative
humidity

Maximum
wet bulb
temperature
Operating
10°C to 35°C
(50°F to 95°F)

0 to 914 m
(0 to 2998 ft.)

8% to 80%
noncondensing
23°C (74°F )

10°C to 32°C
(50°F to 88°F)

914 to 2133 m
(2998 to 6988 ft.)

8% to 80%
noncondensing
23°C (74°F )
Powered off
10°C to 43°C
(50°F to 110°F)
-
8% to 80%
noncondensing
27°C (81°F )
Storing
1°C to 60°C
(34°F to 140°F)

0 to 2133 m
(0 to 6988 ft.)

5% to 80%
noncondensing
29°C (84°F)
Shipping
-20°C to 60°C
(-4°F to 140°F)

0 to 10668 m
(0 to 34991 ft.)

5% to 100%
condensing,
but no precipitation
29°C (84°F)
Heat output (maximum)

350 watts (1195 Btu per hour)

Related topics Installation planning Preparing your uninterruptible power supplyinternal battery backup environment

(C) Copyright International Business Machines Corporation 2003, 2004