Removing the SAN Volume Controller power supply
The following task describes how
to remove the power supply.
Steps
Perform the following steps to remove the power supply:
- Remove all power from the SAN Volume Controller.
- Remove the SAN Volume Controller from the rack.
- Remove the top cover of the SAN Volume Controller.
- Refer to Figure 143.
Figure 143. Removing the power supply
- Remove the disk drive fan.
- Press down on the clip 1 at the front of the power-cable
module and slide the module toward the front of the SAN Volume Controller until the alignment
tab is free of the slot that is on the side of the SAN Volume Controller.
- Lift the power-cable module out from the SAN Volume Controller as far as its cable allows,
and put it to one side.
- Disconnect the power connector 2 .
- Remove the screw 3 .
- Slide the power supply 4 forward, then lift it from the SAN Volume Controller.
The power supply is a complete FRU. Do not try to repair or exchange any
part of it.
 | Note: For a translation of the
following notice, see IBM TotalStorage
Open Software Family SAN Volume Controller Translated Safety Notices. |
 | DANGER Do not try to open the covers
of the power supply assembly. (32) |
- If you have any other tasks to do inside the SAN Volume Controller, do those tasks now.
Otherwise, reinstall parts in the reverse sequence.