>>- svcinfo -- -- lscontroller -- ------------------------------> >--+--------------------------------+-- --+----------+-- -------> '- -filtervalue -- attrib=value -' '- -nohdr -' >--+-----------------------+-- --+-------------+-- -------------> '- -delim -- delimiter -' +- object_id -+ '- name ------' >--+-----------------+----------------------------------------->< '- -filtervalue? -'
| Note: If there is no data to be displayed (for example, an empty view has been returned), then headings are not displayed irrespective of whether the -nohdr option was used or not. |
This command will return a concise list or a detailed view, of controllers visible to the cluster.
The following list provides possible values that are applicable to the
attributes that are displayed as data in the output views:
degraded no, yes
Determining a storage controllers name from its SAN Volume Controller name: List the storage controllers by issuing the svcinfo lscontroller command. Remember the controller name or ID for the controller you want to determine. For the controller in question, issue the svcinfo lscontroller <controllername/id> command, where <controllername/id> is the controller name or ID. Remember the WWNN for the controller. Make a written record of it. The WWNN can be used to determine the actual storage controller by launching the native controller user interface or using the command line tools it provides to verify the actual controller that has this WWNN.
Determining the relationship between MDisks and RAID arrays or LUNs: Each MDisk corresponds with a single RAID array, or a single partition on a given RAID array. Each RAID controller will define a LUN number for this disk. The LUN number and controller name or ID are needed to be able to determine the relationship between mdisks and RAID arrays or partitions.
Show the detailed view of the given MDisk <mdiskname>, by issuing the svcinfo lsmdisk <mdiskname> command, where <mdiskname> is the name of the MDisk.
| Note: Remember the controller name or controller ID and controller LUN number. |
Show the detailed view of the controller determined in by issuing the svcinfo lscontroller <controllername> command, where <controllername> is the name of the controller.
| Note: Remember the vendor ID, product ID, and WWNN. Use these to determine what is being presented to the MDisk. |
From the native user interface for the given controller, list the LUNs it is presenting and match the LUN number. This will tell you the exact RAID array or partition that corresponds with the MDisk.
A concise invocation example
svcinfo lscontroller -delim :
The concise resulting output
id:controller_name:ctrl_s/n:vendor_id:product_id_low:product_id_high 7:controller7:3EK0J5Y8:SEAGATE :ST373405:FC 8:controller8:3EK0J6CR:SEAGATE :ST373405:FC 9:controller9:3EK0J4YN:SEAGATE :ST373405:FC 10:controller10:3EK0GKGH:SEAGATE :ST373405:FC 11:controller11:3EK0J85C:SEAGATE :ST373405:FC 12:controller12:3EK0JBR2:SEAGATE :ST373405:FC 13:controller13:3EKYNJF8:SEAGATE :ST373405:FC 14:controller14:3EK0HVTM:SEAGATE :ST373405:FC
A detailed invocation example
svcinfo lscontroller -delim = 7
The detailed resulting output
id=7 controller_name=controller7 WWNN=20000004CF2412AC mdisk_link_count=1 max_mdisk_link_count=1 degraded=no vendor_id=SEAGATE product_id_low=ST373405 product_id_high=FC product_revision=0003 ctrl_s/n=3EK0J5Y8 WWPN=22000004CF2412AC path_count=1 max_path_count=1 WWPN=21000004CF2412AC path_count=0 max_path_count=0