Switch zoning limitations for the HP StorageWorks subsystem Configuring the HP StorageWorks subsystem Quorum disks on HP StorageWorks

This topic discusses the switch zoning limitations and connection to the SAN.

Attention: Attention: HSG80 based subsystems are supported with a single controller or dual controllers in the subsystem. Since the SAN Volume Controller only supports configurations in which the HSG80 cache is enabled in write-back mode, running with only a single controller in the HSG80 subsystem results in a single point of data loss.
Switch zoning

For code version 1.1.1, regardless of whether the subsystem uses one or two HSG80 controllers, only a single fibre-channel (FC) port attached to the subsystem can be present in a switch zone that contains SAN Volume Controller FC ports. This guarantees that the nodes in the cluster can access at most one port on an HSG80 subsystem.

For code version 1.2.0, switches should be zoned so that ports on the HSG80 are in the switch zone which contains all ports of the SAN Volume Controller nodes.

Connecting to the SAN

Multiple ports from an HSG80 should be physically connected to the fibre-channel SAN in order to enable servicing of the subsystem. However, switch zoning must be used in the manner outlined in this topic.

Note:Note: If the HPQ Command Console is not able to access an FC port on each of the controllers in a two-controller subsystem, there is a risk of an undetected single point of failure.
Related topics Configuring the HP StorageWorks subsystem Quorum disks on HP StorageWorks

(C) Copyright International Business Machines Corporation 2003, 2004