Sharing the HP StorageWorks controller between
a host and the SAN Volume Controller
The HP StorageWorks controller
can be shared between a host and a SAN Volume Controller. This topic briefly discusses the
restrictions.
- A host must not be connected to both a SAN Volume Controller and a HP StorageWorks HSG80
subsystem at the same time.
- Controller ports must not be shared between a host and a SAN Volume Controller. Specifically,
if a controller port is being used by a SAN Volume Controller it must not be present in a
switch zone which enables a host to access the port.
- LU's and RAID arrays must not be shared between a host and a SAN Volume Controller.
- Partitions in the same container must all be either on the SAN Volume
Controller or on hosts.