Port settings for the HP StorageWorks Configuring settings for the HP StorageWorks LU settings for the HP StorageWorks

Only one port per HSG80 pair may be used with the SAN Volume Controller. Port settings are configurable at the port level. This topic lists those per port settings, what the HSG80 defaults are, and what the required settings are for the SAN Volume Controller.

Note:Note: These port settings are set using the following commands:
  • SET THIS PORT_1_TOPOLOGY=FABRIC
  • SET THIS PORT_2_TOPOLOGY=FABRIC
  • SET OTHER PORT_1_TOPOLOGY=FABRIC
  • SET OTHER PORT_2_TOPOLOGY=FABRIC
These values can be checked using the following commands:
  • SHOW THIS
  • SHOW OTHER
Table 54. HSG80 port settings supported by the SAN Volume Controller
Option HSG80 Default Setting HSG80 SAN Volume Controller Required Setting
PORT_1/2-AL-PA 71 or 72 n/a
PORT_1/2_TOPOLOGY Not defined FABRIC
Note:Note: The HSG80 supports LUN masking using the "SET <unit number> ENABLE_ACCESS_PATH command. When used with a SAN Volume Controller, ENABLE_ACCESS_PATH must be set to all ("SET <unit number> ENABLE_ACCESS_PATH=ALL") and all LUN masking handled exclusively by the SAN Volume Controller. The access rights can be checked using the "SHOW CONNECTIONS FULL" and any UNIT_OFFSETs using the "SHOW CONNECTIONS FULL" command.
Related topics Configuring settings for the HP StorageWorks LU settings for the HP StorageWorks

(C) Copyright International Business Machines Corporation 2003, 2004