LU settings for the HP StorageWorks Configuring settings for the HP StorageWorks Connection settings for the HP StorageWorks

LU settings are configurable at the LU level. This topic lists those settings, what the HSG80 defaults are, and what the required settings are for the SAN Volume Controller.

Table 55 describes the options that must be set for each logical unit that is accessed by the SAN Volume Controller. LUs that are accessed by hosts can be configured differently.

Table 55. HSG80 LU settings supported by the SAN Volume Controller
Option HSG80 Default Setting SAN Volume Controller Required Setting
TRANSFER_RATE_REQUESTED 20MHZ n/a
TRANSPORTABLE/ NOTRANSPORTABLE NOTRANSPORTABLE NOTRANSPORTABLE
ENABLE_ACCESS_PATH/DISABLE_ACCESS_PATH ENABLE_ACCESS_PATH=ALL ENABLE_ACCESS_PATH=ALL
IDENTIFIER/ NOIDENTIFIER NOIDENTIFIER n/a
MAX_READ_CACHE_SIZE 32 n/a
MAX_WRITE_CACHE_SIZE 32 64 or higher
MAX_CACHED_TRANSFER_SIZE 32 n/a
PREFERRED_PATH/ NOPREFERRED_PATH NOPREFERRED_PATH is set n/a
READ_CACHE/ NOREAD_CACHE READ_CACHE n/a
READAHEAD_CACHE/ NOREADAHEAD_CACHE READAHEAD_CACHE n/a
RUN/ NORUN RUN RUN
WRITE_LOG/NOWRITE_LOG NOWRITE_LOG NOWRITE_LOG
WRITE_PROTECT/ NOWRITE_PROTECT NOWRITE_PROTECT NOWRITE_PROTECT
WRITEBACK_CACHE/NOWRITEBACK_CACHE WRITEBACK_CACHE WRITEBACK_CACHE
Related topics Configuring settings for the HP StorageWorks Connection settings for the HP StorageWorks