Mapping and virtualization settings for the HP StorageWorks Configuring settings for the HP StorageWorks

This topic discusses LUN mapping or masking and virtualization from the point of view of the HSG80 controller and their use in a SAN Volume Controller environment.

The HSG80 configuration interface requires you assign a unit number to each logical unit when it is defined. By default the LUN is the unit number. It is therefore possible for gaps to exist in the LUN range if the unit numbers used in the configuration commands are not contiguous. By default, each LUN is visible on all controller ports on both controllers.

LUN masking

The HSG80 supports the concept of connection names. It supports a maximum of 96 connection names which contain the following parameters:

Note:Note: The SAN Volume Controller ports should not be in the REJECTED_HOSTS list. This list can be seen with SHOW CONNECTIONS FULL.

LUN masking must not be used on LUs which are in use by the SAN Volume Controller to restrict either the initiator ports or the Target ports which the SAN Volume Controller uses to access the LUs. Configurations that use LUN masking in this way are not supported. LUN masking can be used to prevent other initiators on the SAN from accessing LUs which are in use by the SAN Volume Controller but the preferred method for this is to use SAN zoning.

LU Virtualization

The HSG80 also provides LU virtualization by the port and by the initiator. This is achieved by specifying a UNIT_OFFSET for the connection. The use of LU Virtualization for connections between the HSG80 target ports and initiator ports on the SAN Volume Controller is not supported.

Related topics Configuring settings for the HP StorageWorks