Controller settings for the HP StorageWorks Configuring settings for the HP StorageWorks Port settings for the HP StorageWorks

Controller settings are settings that apply across one HSG80 controller. This topic lists those settings.

Table 53 describes the options that can be set by HSG80 command-line interface (CLI) commands for each controller.

Table 53. HSG80 controller settings supported by the SAN Volume Controller
Option HSG80 Default Setting SAN Volume Controller Required Setting
ALLOCATION_CLASS 0 Any value
CACHE_FLUSH_TIME 10 Any value
COMMMAND_CONSOLE_LUN Not defined Any value
CONNECTIONS_UNLOCKED CONNECTIONS_UNLOCKED CONNECTIONS_UNLOCKED
NOIDENTIFIER Not defined No identifier
MIRRORED_CACHE Not defined Mirrored
MULTIBUS_FAILOVER Not defined MULTIBUS_FAILOVER
NODE_ID Worldwide name as on the label Default
PROMPT None Any value
REMOTE_COPY Not defined Any value
SCSI_VERSION SCSI-2 SCSI-3
SMART_ERROR_EJECT Disabled Any value
TERMINAL_PARITY None Any value
TERMINAL_SPEED 9600 Any value
TIME Not defined Any value
UPS Not defined Any value
Related topics Configuring settings for the HP StorageWorks Port settings for the HP StorageWorks

(C) Copyright International Business Machines Corporation 2003, 2004