Before you complete the hardware location chart, follow these basic rules:
| Note: A cluster can contain no more than four SAN Volume Controllers. |
For this example, assume that the rack is empty and you want to create a system that contains the following components:
Your completed chart might look like the following:
| EIA 36 | Blank |
| EIA 35 | Ethernet Hub 1 |
| EIA 34 | Blank |
| EIA 33 | Blank |
| EIA 32 | Blank |
| EIA 31 | Blank |
| EIA 30 | Blank |
| EIA 29 | Blank |
| EIA 28 | FC Switch 1 |
| EIA 27 | FC Switch 2 |
| EIA 26 | Blank |
| EIA 25 | Blank |
| EIA 24 | Blank |
| EIA 23 | Blank |
| EIA 22 | SAN Volume Controller 4 |
| EIA 21 | SAN Volume Controller 3 |
| EIA 20 | SAN Volume Controller 2 |
| EIA 19 | SAN Volume Controller 1 |
| EIA 18 | Master console |
| EIA 17 | Master console keyboard and monitor |
| EIA 16 | RAID Controller 4 |
| EIA 15 | |
| EIA 14 | |
| EIA 13 | RAID Controller 3 |
| EIA 12 | |
| EIA 11 | |
| EIA 10 | RAID Controller 2 |
| EIA 9 | |
| EIA 8 | |
| EIA 7 | RAID Controller 1 |
| EIA 6 | |
| EIA 5 | |
| EIA 4 | uninterruptible power supply 2 |
| EIA 3 | |
| EIA 2 | uninterruptible power supply 1 |
| EIA 1 |
You might want to put the switches between the SAN Volume Controller nodes. Remember, however, that the uninterruptible power supply units must be in the lowest positions of the rack.
IBM does not install the Ethernet hub or the fibre channel switches. You must arrange for either the suppliers or someone in your organization to install those items. Provide the installer with a copy of the completed hardware location chart.