Switch zoning limitations for the EMC CLARiiON Configuring the EMC CLARiiON controller Quorum disks on the EMC CLARiiON

This topic discusses the supported switch zoning limitations for the SAN Volume Controller and EMC CLARiiON.

The number of connections (process logins) consumed by the SAN Volume Controller cluster and the EMC CLARiiON must be carefully considered. For a single fabric, the number of connections is:

The EMC CLARiiON CX200 provides 2 ports and supports 30 connections. Using a single SAN fabric, a four-node cluster requires 32 connections (4 * 4 * 2). This exceeds the CX200 capability and exposes the SAN Volume Controller cluster integrity.

The solution is to either zone the fabric, or have two fabrics such that only two ports on each SAN Volume Controller node are visible to each CX200 port. Each zone/fabric therefore consumes 8 connections (4 * 2 * 1) and the CX200 only deals with 16 connections.

The SAN Volume Controller is limited to a 2 node cluster with a maximum of 7 hosts.

EMC CLARiiON FC4700 and CX400 systems provide 4 ports and support 64 connections. Using a single SAN fabric, a four-node cluster requires 64 connections (4 * 4 * 4). This equals the EMC CLARiiON capabilities and is therefore only a problem if split support with other hosts is required.

Related topics Configuring the EMC CLARiiON controller Quorum disks on the EMC CLARiiON

(C) Copyright International Business Machines Corporation 2003, 2004