LU settings for the EMC CLARiiON
LU settings are configurable at
the LU level. This topic lists those settings, the EMC CLARiiON defaults,
and required settings are for the SAN Volume Controller.
Table 23 describes the options that must
be set for each logical unit that is accessed by the SAN Volume Controller. LUs that are accessed
by hosts can be configured differently.
Table 23. EMC CLARiiON LU settings supported by the SAN Volume Controller
|
Option |
EMC CLARiiON Default
Setting |
SAN Volume Controller Required
Setting |
| LU ID |
Auto |
N/A |
| RAID Type |
5 |
Any RAID Group |
| RAID Group |
Any available RAID Group |
Any available RAID Group |
| Offset |
0 |
Any setting |
| LU Size |
ALL LBAs in RAID Group |
Any setting |
| Placement |
Best Fit |
Either Best Fit or First Fit |
| UID |
N/A |
N/A |
| Default Owner |
Auto |
N/A |
| Auto Assignment |
Disabled |
Disabled |
| Verify Priority |
ASAP |
N/A |
| Rebuild Priority |
ASAP |
N/A |
| Strip Element Size |
128 |
N/A |
| Read Cache Enabled |
Enabled |
Enabled |
| Write Cache Enabled |
Enabled |
Enabled |
| Idle Threshold |
0-254 |
0-254 |
| Max Prefetch Blocks |
0-2048 |
0-2048 |
| Maximum Prefetch IO |
0-100 |
0-100 |
| Minimum Prefetch Size |
0-65534 |
0-65534 |
| Prefetch Type |
0, 1, or 2 |
0, 1, or 2 |
| Prefetch Multiplier |
0 to 2048 or 0 to 324 |
0 to 2048 or 0 to 324 |
| Retain prefetch |
Enabled or Disabled |
Enabled or Disabled |
| Prefetch Segment Size |
0 to 2048 or 0 to 32 |
0 to 2048 or 0 to 32 |
| Idle Delay Time |
0 to 254 |
0 to 254 |
| Verify Priority |
ASAP, High, Medium, or Low |
Low |
| Write Aside |
16 to 65534 |
16 to 65534 |
 | Note: The SAN Volume Controller cannot obtain or change the configuration options
listed above. It is therefore your responsibility to configure the options
as recommended. |
Related topics