Concurrent maintenance on the EMC CLARiiON
Concurrent maintenance of the EMC
CLARiiON is supported with the SAN Volume Controller.
Concurrent maintenance is the ability to perform I/O operations to a controller
while simultaneously performing maintenance on it. This topic lists the components
of the EMC CLARiiON that can be maintained in this way.
The EMC CLARiiON model FC series allows for concurrent replacement of the
following components:
- Disk drives
- Controller fans (Fans must be replaced within 2 minutes or controllers
will shut down.)
- Disk enclosure fans (Fans must be replaced within 2 minutes or controllers
will shut down.)
- Controller (Service Processor: cache must be disabled first)
- Fibre Channel Bypass cards (LCC)
- Power supplies (Fans must be removed first.)
- UPS battery (SPS)
The EMC CLARiiON model CX series allows for concurrent replacement of the
following components:
- Disk drives
- Controller (Service processor or drawer controller)
- Power/cooling modules (Modules must be replaced within 2 minutes or controllers
will shut down.)
- UPS battery (SPS)
 | Notes:
- EMC CLARiiON procedures for concurrent upgrade must be followed in all
cases.
- The CX Series also has a feature called Data In Place Upgrade which allows
you to upgrade from one model to another (for example, from the CX200 to the
CX600) with no data loss or migration required. This is not supported by the SAN Volume Controller.
|