Event notification IBM Director Call-Home test

This task provides step-by-step instructions about setting up your event notification for the SAN Volume Controller. Event notification enables system administrators to receive e-mail notifications about problems with the SAN Volume Controller.

The Event notification configuration has already been partially completed during manufacture.

Steps

Perform the following steps to set up your e-mail notification:

  1. Start IBM Director by clicking the IBM Director Console icon on the desktop.
  2. From the IBM Director Console menu bar, select Tasks ->Event Action Plan Builder.
  3. In the Actions column, expand the item Send an Internet (SMTP) E-mail.
  4. Right-click 2145EventNot and select Update. The Customize Action: 2145EventNot panel displays.
  5. Fill in the following items:

    Internet E-mail Address

    • Fill in an e-mail address (for example, the e-mail address of the system administrator)

    Reply to

    • Fill in the e-mail address to which you want any replies to be directed.

    SMTP E-mail Server

    • Fill in the address of your e-mail server.

    SMTP Port

    • Change this, if required, to your SMTP server port number.

    Subject of E-mail Message

    • Ensure that 2145 Event Notification is displayed in the Subject of E-mail message field.

    Body of the E-mail Message

    • Fill in the following information:
      • Machine location
      This information will replace the xxxx shown in the Body of E-mail message field.
      Note:Note: Ensure that you only replace the xxxxx and delete (Maximum 72 chars).
  6. Click File -> Save to save the information. The window will close.
  7. Close the Event Action Plan Builder window.
  8. Close the IBM Director Console window.

The following is an example of a completed body of the e-mail message:
# Machine location = Data Centre 1
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.1
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.2
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.3
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.4
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.5
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.6
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.7
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.8
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.9
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.10
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.11
&iso.org.dod.internet.private.enterprises.ibm.ibmProd.190.4.12

Result

This has completed the IBM Director SAN Volume Controller Call-Home set up. Ensure that you verify that Call-Home has been configured correctly.

Related topics IBM Director Call-Home test