Storage subsystems Concepts Host objects

A storage subsystem is a device that coordinates and controls the operation of one or more disk drives and synchronizes the operation of the drives with the operation of the system as a whole.

Storage subsystem attached to the SAN fabric provide the physical storage devices that the cluster detects as managed disks. These are usually RAID arrays as the SAN Volume Controller does not attempt to provide recovery from physical disk failures within the storage subsystem. The nodes in the cluster are connected to one or more Fibre Channel SAN fabrics.

The exported storage devices are detected by the cluster and reported by the user interfaces. The cluster can also determine which managed disks each storage subsystem is presenting, and can provide a view of managed disks filtered by the storage subsystem. This allows you to associate the managed disks with the RAID arrays that the subsystem exports.

The storage subsystem may have a local name for the RAID arrays or single disks that it is providing. However it is not possible for the nodes in the cluster to determine this name as the namespace is local to the storage subsystem. The storage subsystem will surface these storage devices with a unique ID, the logical unit number (LUN). This ID, along with the storage subsystem serial number or numbers (there may be more than one controller in a storage subsystem), can be used to associate the managed disks in the cluster with the RAID arrays exported by the subsystem.

Storage subsystems export storage to other devices on the SAN. The physical storage associated with a subsystem is normally configured into RAID arrays which provide recovery from physical disk failures. Some subsystems also allow physical storage to be configured as RAID-0 arrays (striping) or as JBODs; however, this does not provide protection against a physical disk failure and with virtualization can lead to the failure of many virtual disks.

Many storage subsystems allow the storage provided by a RAID array to be divided up into many SCSI logical units (LUs) which are presented on the SAN. With the SAN Volume Controller it is recommended that storage subsystems are configured to present each RAID array as a single SCSI LU which will be recognized by the SAN Volume Controller as a single managed disk. The virtualization features of the SAN Volume Controller can then be used to divide up the storage into virtual disks.

Some storage subsystems allow the exported storage to be increased in size. The SAN Volume Controller will not use this extra capacity. Instead of increasing the size of an existing managed disk, a new managed disk should be added to the managed disk group and the extra capacity will be available for the SAN Volume Controller to use.

Attention: Attention: If you delete a RAID that is being used by the SAN Volume Controller, the MDisk group will go offline and the data in that group will be lost.

When configuring your storage subsystems, ensure that you configure and manage your subsystems and its devices for optimal performance.

The cluster detects and provides a view of the storage subsystems that the SAN Volume Controller supports. The cluster can also determine which MDisks each subsystem has and can provide a view of MDisks filtered by device. This view enables you to associate the MDisks with the RAID arrays that the subsystem presents.

Note:Note: The SAN Volume Controller Console supports storage that is internally configured as a RAID array. However, it is possible to configure a storage subsystem as a non-RAID device. RAID provides redundancy at the disk level. Therefore, a single physical disk failure does not cause an MDisk failure, an MDisk group failure, or a failure in the virtual disks (VDisks) that were created from the MDisk group.

Storage subsystems reside on the SAN fabric and are addressable by one or more fibre-channel ports (target ports). Each port has a unique name known as a worldwide port name (WWPN).

Related topics Concepts Host objects

(C) Copyright International Business Machines Corporation 2003, 2004