You can determine the failing enclosure or disk controller by using the SAN Volume Controller user interface or the command-line interface.
Type the following command to list all the mdisks:
svcinfo lsmdisk -nohdr -delim :
Type the svcinfo lsmdisk -nohdr -delim : command to see what might display in the following example:
0:mdisk0:online:managed:0:mdiskgrp0:273.3GB:0000000000000001:controller0:* 1:mdisk1:excluded:managed:0:mdiskgrp0:546.6GB:0000000000000002:controller0:+ * 600a0b80000c5ae4000000093eca105c00000000000000000000000000000000 is appended to this line. + 600a0b80000f6432000000043ef6b4ff00000000000000000000000000000000 is appended to this line.
The mdisks are listed in the object ID order. The first item is the object ID, the third item is the status, and the ninth item is the disk or controller name. In the example above, mdisk1 has an object ID of 1, is failing with the status excluded, and is part of a disk controller named controller0.
To obtain the detailed data for the named enclosure or disk controller, type the following command:
svcinfo lscontroller -delim : name
where name is the enclosure disk controller name.
To obtain detailed data for controller0, type the following command:
svcinfo lscontroller -delim : controller0
The following detailed data is displayed:
id:0 controller_name:controller0 WWNN:200200A0B80F5E2C mdisk_link_count:30 max_mdisk_link_count:30 degraded:no vendor_id:IBM product_id_low:1722-600 product_id_high: product_revision:0520 ctrl_s/n: WWPN:200200A0B80F5E2D path_count:30 max_path_count:30 WWPN:200300A0B80F5E2D path_count:30 max_path_count:30