Configuring the HP StorageWorks controller HP StorageWorks controllers Supported models of the HP StorageWorks controller

This task provides step-by-step instructions for configuring the HP StorageWorks HSG80 controller. It describes a process that is required to connect an HP StorageWorks subsystem to an SAN Volume Controller.

Prerequisites

Assume that the HP StorageWorks subsystem is not in use.

Steps

Perform the following steps to configure the HSG80 controller:

  1. Verify that the SAN Volume Controller front panel is clear of errors.
  2. Ensure that the HP StorageWorks Operator Control Panel (OCP) on each HSG80 controller is clear of errors. The Operator Control Panel consists of seven green LED's at the rear of each HSG80 controller.
  3. Ensure that you can use an HP StorageWorks command-line interface (CLI) to configure the HSG80 controllers.
  4. Issue the SHOW THIS command and SHOW OTHER command to verify the following:
    • That the controller software is at the supported level. See

      http://www.ibm.com/storage/support/2145/.

    • Ensure that the controllers are configured for MULTIBUS FAILOVER with each other.
    • Ensure that the controllers are running in SCSI-3 mode.
    • Ensure that MIRRORED_CACHE is enabled.
    • Ensure that the Host Connection Table is not locked.
  5. Issue the SHOW DEVICES FULL command to verify the following:
    • Ensure that none of the LUNs are TRANSPORTABLE.
    • Ensure that all LUNs are configured. For example, the LUNs report their serial numbers and TRANSFER_RATE_REQUESTED correctly.
  6. Issue the SHOW FAILEDSET command to verify that there are no failing disks.
    Note:Note: To verify, there should be no orange lights on any disks in the subsystem.
  7. Issue the SHOW UNITS FULL command to verify the following:
    • Ensure that all LUNs are set to RUN and NOWRITEPROTECT
    • Ensure that all LUNs are ONLINE to either THIS or OTHER controller.
    • Ensure that all LUNs that are to be made available to the SAN Volume Controller have ALL access.
    • Ensure that all LUNs have Host Based Logging NOT specified.
    If you have partitioned LUNs, refer to the HP StorageWorks controllers topic.
  8. Issue the SHOW CONNECTIONS FULL command to verify that you have enough spare entries for all combinations of SAN Volume Controller ports and HP StorageWorks ports.
  9. Connect up to four known good fibre-channel cables between your fibre-chanel switches and your HP StorageWorks subsystem.
  10. Ensure that your fibre-channel switches are zoned such that the SAN Volume Controller and the HP StorageWorks subsystem are in a zone. Refer to zoning a switch.
  11. Issue the SHOW THIS command and SHOW OTHER command to verify that each connected port is running. Something similar to the following output should be displayed:PORT_1_TOPOLOGY=FABRIC (fabric up).
  12. Issue the SHOW CONNECTIONS FULL command to verify that the new connections have appeared for each SAN Volume Controller port and HP StorageWorks port combination.
  13. Verify that No rejected hosts is displayed at the end of the SHOW CONNECTIONS output.
  14. On the SAN Volume Controller, issue the svctask detectmdisk command to discover the controller.
  15. Issue the svcinfo lscontroller command to verify that the two HSG80 serial numbers appear under the ctrl s/n.
  16. Issue the svcinfo lsmdisk command to verify that the additional MDisks that correspond to the UNITS shown in the HP StorageWorks subsystem.
Result

You can now use the SAN Volume Controller commands to create an MDisk group. You can also create and map VDisks from these MDisk groups. Check your SAN Volume Controller front panel has no errors. If you ensure that your host has reloaded its fibre-channel driver then you should be able to perform I/O to the VDisks. See the IBM TotalStorage SAN Volume Controller: Host Attachment Guide for detailed information.

Related topics HP StorageWorks controllers Supported models of the HP StorageWorks controller