This topic describes steps you must perform before you configure the SAN Volume Controller.
Perform the following steps:
When creating RAID with parity protection (for example, RAID 5), consider how many component disks to use in each array. The more disks you use, the fewer disks you need to provide availability for the same total capacity (one per array). However, if you use more disks, it will take longer to rebuild a replacement disk after a disk failure. If a second disk failure occurs during the rebuild period, all data on the array is lost. More data is affected by a disk failure for a larger number of member disks resulting in reduced performance while rebuilding onto a hot spare and more data being exposed if a second disk fails before the rebuild has completed. The smaller the number of disks, the more likely it is that write operations span an entire stripe (strip size x number of members minus 1). In this case, write performance is improved because the disk write operations do not have to be preceded by disk reads. The number of disk drives required to provide availability might be unacceptable if the arrays are too small.
When in doubt, create arrays with between six and eight member disks.
If reasonably small RAID arrays are used, it is easier to extend an MDisk group by adding a new RAID array of the same type. Construct multiple RAID devices of the same type, when possible.
When creating RAID with mirroring, the number of component disks in each array does not affect redundancy or performance.
Most back-end disk controller systems enable RAID to be divided up into more than one SCSI logical unit (LU). When configuring new storage for use with the SAN Volume Controller, you do not need to divide up the array. New storage should be presented as one SCSI LU. This will give a one-to-one relationship between MDisks and RAID.
| Attention: Losing an array in an MDisk group can result in the loss of access to all MDisks in that group. |
| Note: The SAN Volume Controller and the master console are defined in each zone. |
http://www-1.ibm.com/server/storage/support/software/sdd.html
Be sure to install version 1.4.x.x or higher.
| Note: You can also install the master console on another machine (which you provide) using the a CD-ROM provided with the master console. |
Notes:
|
When you and the IBM service representative have completed the initial preparation steps, you must: