Known issues and limitations Requirements for attaching to an IBM RS/6000 or IBM eserver_logo pSeries host

This information provides a reference to known issues and limitations with the SAN Volume Controller and an AIX host.

On heavily loaded systems, you might see lower than expected performance without any errors being logged. One possible cause is that the host is low on DMA resources.

On a heavily loaded system you might see errors indicating that the host bus adapter (HBA) was unable to activate an I/O request on the first attempt. The most likely cause of these errors is that the host is low on DMA resources.

To reduce the incidence of these messages you can increase the resources by modifying the maximum transfer size attribute for the adapter as follows:

  1. Type the following command to view the current setting:
    lsattr -El <HBA> -a max_xfer_size
    where HBA is the name of the adapter logging the error. For this example the HBA is fcs0.
  2. Type the following command to increase the size of the setting:
    chdev -l fcs0 -P -a max_xfer_size=0x1000000
    Note:Note: To view the range of allowable values for the attribute, type: lsattr -Rl fcs0 -a max_xfer_size
    Restart the host to put these changes into effect.