Adding a new storage controller to a running configuration using the SAN Volume Controller Console Disk Controller Systems Changing a configuration for an existing storage subsystem

This task provides step-by-step instructions for adding a new storage controller to a running configuration.

Prerequisites

You can add a new storage controller to your SAN at any time. Follow the switch zoning guidelines and also ensure the controller is setup correctly for use with the SAN Volume Controller.

You should create one or more arrays on the new controller. It is recommend that you use, RAID-5, RAID-1 or RAID-0+1 (sometimes called RAID-10) for maximum redundancy and reliability. Generally 5+P arrays are recommend. If your controller provides array partitioning we recommend that you create a single partition from the entire capacity available in the array, remember the LUN number that you assign to each partition as you will need this later. You should also follow the mapping guidelines (if your storage controller requires LUN mapping) to map the partitions or arrays to the SAN Volume Controller ports. You can determine the SAN Volume Controller ports by following the procedure for determining WWPNs..

Steps

Perform the following steps to add a new storage controller to a running configuration:

  1. To ensure that the cluster has detected the new storage (MDisks) click Work with MDisks and select the Detect MDisks task.
  2. The controller itself will have automatically been assigned a default name. If you are unsure which controller is presenting the MDisks click Work with Disk Controllers. You should see a new controller listed (the one with the highest numbered default name). You must determine the storage controller name to validate that this is the correct controller.
  3. Close and re-open the Work with MDisks panel using the filter panel to select a mode of unmanaged and a controller name that corresponds with the new controller's name. The MDisks shown should correspond with the RAID arrays or partitions you have created. Remember the field controller LUN number, this corresponds with the LUN number you assigned to each of the arrays or partitions.
  4. It is recommended that you create a new managed disk group and add only the RAID arrays that belong to the new controller to this MDisk group. You should also avoid mixing RAID types, so for each set of RAID array types (for example, RAID-5, RAID-1) you should create a new MDisk group. Give this MDisk group an appropriate name, so if your controller is called FAST650-fred, and the MDisk group contains RAID-5 arrays, call it something like F600-fred-R5.
  5. Click Work with MDisk group from the portfolio. Select the Create MDisk group task. On the new panel, enter the name you wish to give this group, select the MDisks you wish to add from the list and click Add. Select the extent size you wish this group to have and click OK.
Related topics Disk Controller Systems Changing a configuration for an existing storage subsystem