The SAN Volume Controller has lost power without saving data. When the cluster is available
The SAN Volume Controller will rejoin the cluster. However, this SAN Volume Controller cannot access the cluster
at this time.
Action:
Repair failures on any other SAN Volume Controllers that might be preventing a cluster
form being formed.
Display the Fibre Channel port status on this SAN Volume Controller and repair any fibre
channel paths that do not have a status of Active.
Verify with the customer that no changes have been made to the fibre channel
switch zoning or cabling that might prevent this node being able to access
other SAN Volume Controllers in the cluster. If changes have been made then reverse those
changes to enable this SAN Volume Controller to rejoin the cluster.
If more than one SAN Volume Controller is displaying this error code on its front panel,
those SAN Volume Controllers have simultaneously lost power without saving data. This might
have been caused by simultaneous failures of SAN Volume Controller power supplies, SAN Volume Controller UPS
assemblies or the simultaneous accidental removal of SAN Volume Controller power cables. This
might result in the total loss of the cluster. Call your support center for
assistance.