Inspecting the SAN Volume Controller for unsafe conditions External machine checks Inspecting the uninterruptible power supply for unsafe conditions

Be cautious of potential safety hazards that are not covered in the safety checks. If unsafe conditions are present, determine how serious the hazards are and whether you should continue before correcting the problem.

Prerequisites

Consider the following conditions and the safety hazards they present:

Electrical hazards (especially primary power)
Primary voltage on the frame can cause serious or lethal electrical shock.
Explosive hazards
A bulging capacitor can cause serious injury.
Mechanical hazards
Loose or missing items (for example, nuts and screws) can cause serious injury.
Steps

Using the following inspection checklist as a guide, inspect the IBM(R) TotalStorage(TM) SAN Volume Controller for unsafe conditions. If necessary, see any suitable safety publications.

  1. Turn off the SAN Volume Controller.
  2. Check the frame for damage (loose, broken, or sharp edges).
  3. Check the power cables and ensure that:
    1. The third-wire ground connector is in good condition. Use a meter to check that the third-wire ground continuity is 0.1 ohm or less between the external ground pin and the frame ground.
    2. The insulation is not worn or damaged.
  4. Check for any obvious nonstandard changes. Use good judgment about the safety of any such changes.
  5. Check inside the SAN Volume Controller for any obvious unsafe conditions, such as metal particles, water or other fluids, or marks of overheating, fire, or smoke damage.
  6. Check for worn, damaged, or pinched cables.
  7. Ensure that the voltage specified on the product-information label matches the specified voltage of the electrical power outlet. If necessary, verify the voltage.
  8. Inspect the power supply assemblies, and check that the fasteners (screws or rivets) in the cover of the power-supply unit have not been removed or disturbed.
  9. Before connecting the SAN Volume Controller to the SAN, check the grounding.
Related topics External machine checks Inspecting the uninterruptible power supply for unsafe conditions