Checking the grounding of the SAN Volume Controller and
the uninterruptible power supply
This topic tells you how to check
the grounding of the SAN Volume Controller. Figure 207 shows the connectors for
the SAN Volume Controller and the uninterruptible power supply.
Steps
Perform the following steps to ensure that the SAN Volume Controller is
properly grounded:
-
Ensure that all power is removed.
- Ensure that the power cable 1 is plugged into the uninterruptible
power supply. Also ensure that the other ends of the power cable are connected
to the power supply in the rack. See Figure 207 .
Figure 207. Power cable and signal sockets
- Attention: Some electrical circuits could be damaged
if the external signal cables are present at the SAN Volume Controller while the grounding
check is being done.
Ensure that no external cables are present at connectors 2 and 3 .
- Disconnect and remove the Ethernet cable.
-
Follow your local procedures and check the grounding of the SAN Volume Controller.
Any test equipment must be connected to the frame of the SAN Volume Controller.
If the
grounding is correct, go no further with these instructions.
If the
grounding is not correct, unplug the power cable 1 from the uninterruptible power supply in the SAN Volume Controller.
- Check for continuity between the frame of the SAN Volume Controller and the ground pin 1 of each main power connector as shown in Figure 208.
-
If the uninterruptible power supply has no continuity, exchange
it for a new one. Then perform a complete grounding check again.
If the
uninterruptible power supply has continuity, you might have a problem with
the power cable or with the grounding of the host system.
- Check the power cable for continuity.
If the power cable does not have
continuity, exchange it for a new one, then perform step 1 through
step 5 again.