2010
 
Explanation:

A software upgrade has failed. This might be caused by a hardware error or it might be from a failure in the new version of the software. An automatic software downgrade is performed to restore the SAN Volume Controllers to their previous software version. If the downgrade operation fails to downgrade a SAN Volume Controller (for example because it is offline), the download operation will stop and wait for the offline SAN Volume Controller to be repaired or deleted from the cluster. While the downgrade operation is in progress, configuration commands sent to the cluster will fail with a message indicating that a software upgrade operation is still in progress. The downgrade operation might take up to three hours.

Action:

  1. Display the status of the nodes on the cluster (refer to "Viewing the node status using the SAN Volume Controller Console application on the master console" for the user interface or "Checking the status of the node" for the command line interface).
  2. If any node is offline, delete the offline node from the cluster. See cluster diagnostic and service-aid commands in the IBM TotalStorage SAN Volume Controller: Command-Line Interface User's Guide for detailed information about deleting a node from a cluster. If the delete fails with a message indicating that a software upgrade is in progress, this means that the downgrade process is still active. Wait for this operation to either complete or stop on the offline node and then retry the delete. If the downgrade operation had stopped, it will now continue.
  3. Solve all logged hardware problems.
  4. Ask the user to retry the software install.
  5. If the installation fails again, report the problem to your software support center.
  6. Mark the error you have just repaired as "fixed."
  7. Go to repair verification map.

Possible Cause-FRUs or other:

Other:
Related topics:

(C) Copyright International Business Machines Corporation 2003, 2004