1630
 
Explanation:

The number of device logins was reduced. One possible cause is that the user intentionally reconfigured the system.

Action:

  1. Check the error in the cluster error log to identify the object ID associated with the error.
  2. Check the availability of the failing device using the following command line: svcinfo lscontroller object_ID. If the command fails with the message "CMMVC6014E The command failed because the requested object is either unavailable or does not exist," ask the customer if this device was removed from the system.
    • If "yes," mark the error as fixed in the cluster error log and continue with the repair verification map
    • If "no" or if the command lists details of the failing controller, continue with step 3.
  3. Check whether the device has regained connectivity. If it has not, check the cable connection to the remote-device port.
  4. If all logins to a remote-device port have failed and you cannot solve the problem by changing cables, check the condition of the remote-device port and the condition of the remote device.
  5. Start a cluster discovery operation.
  6. Check the status of the disk controller (refer to "Viewing general details for controllers" for the user interface or Disk controller status for the command line interface). If all disk controllers show a "good" status, mark the error you have just repaired as "fixed." If any disk controllers do not show "good" status, go to start map. If you return to this step, contact the IBM support center to resolve the problem with the disk controller.
  7. Go to repair verification map.

Possible Cause-FRUs or other:

Other:
Related topics:

(C) Copyright International Business Machines Corporation 2003, 2004