1625
 
Explanation:

Incorrect disk controller configuration.

Action:

  1. Using service documentation for the disk controller, check that the correct configuration is set up for the disk controller. See also the IBM TotalStorage SAN Volume Controller: Configuration Guide.
  2. Mark the error you have just repaired as "fixed."
  3. Start a cluster discovery operation.
  4. Go to repair verification map.

Possible Cause-FRUs or other:

Other:

Disk drive enclosure, or disk controller, that is connected to the SAN Volume Controller

Related topics:

(C) Copyright International Business Machines Corporation 2003, 2004