A cluster path has failed. One of the SAN Volume Controller fibre-channel ports is unable
to communicate with all the other SAN Volume Controllers in the cluster.
Action:
Repair the fibre-channel network fabric.
Check the status of the node ports (refer to "Checking the
status of the node ports" for the command line interface). If the status
of the node ports shows as active, mark the error you have just repaired
as fixed. If any node ports do not show a status of active, go to start map.
If you return to this step contact the IBM support center to resolve the problem
with the SAN Volume Controller.