View the error log. Note the mdisk ID
associated with the error code.
Using the mdisk ID, determine the failing disk controller.
Refer to the service documentation for the disk enclosure or disk controller
and the fibre-channel network fabric to resolve the reported problem.
After the disk drive is repaired, start a cluster discovery operation
to recover the excluded fibre-channel port.
Include the managed disk that you noted in step 1.
Check the status of the disk controller (refer to "Viewing
general details for controllers" for the user interface or "Disk controller
status" for the command line interface). If all disk controllers show
a "good" status, mark the error you have just repaired "fixed."
If all disk controllers do not show a good status, contact the IBM support
center to resolve the problem with the disk controller.
Go to repair verification map.
Possible Cause-FRUs or other:
None
Other:
Disk drive enclosure, or disk controller, that is connected to the SAN Volume Controller (50%).