1076
 
Explanation:

The internal temperature sensor of the SAN Volume Controller has reported that the temperature warning threshold has been exceeded.

Action:

  1. Check whether the internal airflow of the SAN Volume Controller has been obstructed. Clear any obstructions. If you cannot find an obstruction, exchange the FRU for a new FRU. See "Possible Cause-FRUs or other" after the last action in this section.
  2. Check node status (refer to "Viewing the node status using the SAN Volume Controller Console application on the master console" for the user interface or "Checking the status of the node" for the command line interface). If all nodes show a status of "online," mark the error you have just repaired "fixed." If any nodes do not show a status of "online," go to start map. If you return to this step, contact the IBM support center to resolve the problem with the SAN Volume Controller.
  3. Go to repair verification map.

Possible Cause-FRUs or other:

Related topics:

(C) Copyright International Business Machines Corporation 2003, 2004