100
 
Explanation:

Boot is running.

Action:

If the progress bar has not advanced for two minutes, the boot process has hung. In the sequence shown, remove the following FRUs. Each time you remove a FRU or a group of FRUs, try the boot operation again. If you return to this error code put back the removed FRU and remove the next FRU in the list. If after removing a FRU you get a new boot code, perform the actions described for that boot code.

  1. All fibre-channel adapter cards. (A fibre-channel Adapter missing error occurs when adapters are removed.)
  2. Bank 1 memory modules. (A memory bank 1 error occurs when the modules are removed.)
  3. Bank 2 memory modules. (A memory bank 2 error occurs when the modules are removed.)
  4. Disk drive assembly. (A disk drive hardware error occurs when the disk drive assembly is removed.)

If the problem remains, exchange, in the sequence shown, the FRUs for new FRUs. After each FRU exchange, try the boot operation again. See "Possible Cause-FRUs or other."

Possible Cause-FRUs or other:

Related topics:

(C) Copyright International Business Machines Corporation 2003, 2004